[AS57/58/67/68 series] Temperature Sensor Follow
For AS5712-54X, AS5812-54X, AS5812-54T, there are use 3 independent thermal sensors.
Boot the switch with Accton Diag and dump temperature from thermal sensors.
diag# diag_main
Diagnostics 2.0.2.9
**********************************************************************
.
(029) Test thermal
.
**********************************************************************
Please enter your choice(Enter 0 to quit): 029
30.9C 30.1C 28.1C
Item (29) test result : SUCCESS
Note, the AS5712-54X, AS5812-54X, AS5812-54T normal operating temperature is 0 to 40 degree C.
If temperature is over 40 degrees thus test result is fail.
For AS6712-32X, AS6812-32X, there are used 4 independent thermal sensors.
Boot the switch with Accton Diag and dump temperature from thermal sensors.
diag# diag_main
Diagnostics 1.0.0.7
**********************************************************************
.
(030) Test thermal
.
**********************************************************************
Please enter your choice(Enter 0 to quit): 030
30.4C 29.0C 28.2C 30.4C
Item (30) test result : SUCCESS
Note, the AS6712-32X, AS6812-32X normal operating temperature is 0 to 40 degree C.
If temperature is over 40 degrees thus test result is fail.
Comments
0 comments
Please sign in to leave a comment.