[FPGA] How to upgrade the FPGA via ONIE? Follow
Purpose:
This post shows the procedures to upgrade FPGA via ONIE on Edgecore switch.
Model:
AS7312-54XS
AS7316-26XB
AS7712-32X
AS7716-32X
Preparation:
A. Personal computer
B. FPGA_Updater
- Download the FPGA-updater image for your own device.
- Reference: How to download the current firmware?
C. Serial Console cable:
- A cable which attached in the original box.
D. Console terminal
- Putty,Teraterm,SecureCRT,etc...
E. Empty USB drive or transport protocol tools
- USB drive
- TFTP server
- FTP server
- Http file server
- OpenSSH
Procedure:
STEP1. Reboot the switch and then press "ESC" to enter the BIOS setting. (e.g., AS7316_26XB)
1. Check the version and then press "ESC".
Note: If your model belongs to AS7316/AS7716 series and the current BIOS version is v36 or later, STEP1 should be processed before the upgrade, else please ignore this step.
*set Lock Chipset to: Disable
*set MSR Lock Control to: Disable
2. Please follow the red marked.
3. Please disable the following red marked
4. Save changes and reset.
STEP2. Start the upgrade process (5 examples)
- USB drive
1. Put the FPGA_Updater to the USB drive. (e.g., AS7712_32X)
2. Insert the USB drive into the data center front panel.
3. The terminal will show the following message.
4.Input "fdisk -l" command to show the storage status (e.g., /dev/sdb)
ONIE:/mnt/usb # fdisk -l
Disk /dev/sda: 31.4 GB, 31488000000 bytes
255 heads, 63 sectors/track, 3828 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start End Blocks Id System
/dev/sda1 * 1 3829 30749999+ ee EFI GPT
Disk /dev/sdb: 4009 MB, 4009754624 bytes
124 heads, 62 sectors/track, 1018 cylinders
Units = cylinders of 7688 * 512 = 3936256 bytes
Device Boot Start End Blocks Id System
/dev/sdb1 ? 253420 474801 850989111+ 6e Unknown
Partition 1 has different physical/logical beginnings (non-Linux?):
phys=(97, 115, 32) logical=(253419, 0, 14)
Partition 1 has different physical/logical endings:
phys=(107, 121, 32) logical=(474800, 17, 54)
Partition 1 does not end on cylinder boundary
/dev/sdb2 ? 1 1 0 74 Unknown
Partition 2 has different physical/logical beginnings (non-Linux?):
phys=(370, 116, 33) logical=(0, 0, 1)
Partition 2 has different physical/logical endings:
phys=(0, 13, 10) logical=(558658, 74, 4)
Partition 2 does not end on cylinder boundary
/dev/sdb4 3649 3649 220+ 0 Empty
Partition 4 has different physical/logical beginnings (non-Linux?):
phys=(0, 0, 0) logical=(3648, 57, 51)
Partition 4 has different physical/logical endings:
phys=(0, 0, 0) logical=(3648, 64, 57)
Partition 4 does not end on cylinder boundary
Partition table entries are not in disk order
Note: /dev/sda is original hard drive, mSATA, 32G
5. Mount the USB drive and check the mount status.
ONIE:/mnt # mkdir /mnt/usb
ONIE:/mnt # mount -v /dev/sdb /mnt/usb
ONIE:/mnt # mount | grep sdb
/dev/sdb on /mnt/usb type vfat (rw,relatime,fmask=0022,dmask=0022,codep age=437,iocharset=iso8859-1,shortname=mixed,errors=re
6. Copy the FPGA_Updater to local storage. (e.g., /tmp)
ONIE:/mnt/usb # ls
AS7712-32X_FPGA_v4.updater
System Volume Information
ONIE:/mnt/usb # cp AS7712-32X_FPGA_v4.updater /tmp
7. Upgrade the FPGA by "install_url [FGPA_Updater]" command.
ONIE:/ # cd /tmp
ONIE:/tmp # ls
AS7712-32X_FPGA_v4.updater
ONIE:/tmp # install_url AS7712-32X_FPGA_v4.updater
8. FPGA will be upgraded immediately.
- TFTP
1. Please connect to the TFTP server with Mgmt port. (e.g., AS7716-32X)
Note: Please use 1G port.
2. Set the IP address in ONIE and try to ping the TFTP server. (Server IP: 192.168.0.200)
ONIE:/ # ifconfig eth0 192.168.0.1 netmask 255.255.255.0
ONIE:/ # ifconfig
eth0 Link encap:Ethernet HWaddr CC:37:AB:C4:B1:0C
inet addr:192.168.0.1 Bcast:192.168.0.255 Mask:255.255.255.0
inet6 addr: fe80::ce37:abff:fec4:b10c/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:77 errors:0 dropped:0 overruns:0 frame:0
TX packets:31 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:7619 (7.4 KiB) TX bytes:7134 (6.9 KiB)
Memory:dff00000-dff1ffff
ONIE:/ # ping 192.168.0.200
PING 192.168.0.200 (192.168.0.200): 56 data bytes
64 bytes from 192.168.0.200: seq=0 ttl=128 time=9.675 ms
64 bytes from 192.168.0.200: seq=1 ttl=128 time=0.517 ms
^C
--- 192.168.0.200 ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.517/5.096/9.675 ms
3. Input "install_url [TFTP file location]" command and the upgrade will start.
ONIE:/ # install_url tftp://192.168.0.200/AS7712-32X_FPGA_v4.updater
4. FPGA will be upgraded immediately.
- FTP
1. Please connect to the FTP server with Mgmt port. (e.g., AS7712-32X)
Note: Please use 1G port.
2. Set the IP address in ONIE and try to ping the FTP server. (Server IP: 192.168.0.200)
ONIE:/ # ifconfig eth0 192.168.0.1 netmask 255.255.255.0
ONIE:/ # ifconfig
eth0 Link encap:Ethernet HWaddr CC:37:AB:C4:B1:0C
inet addr:192.168.0.1 Bcast:192.168.0.255 Mask:255.255.255.0
inet6 addr: fe80::ce37:abff:fec4:b10c/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:77 errors:0 dropped:0 overruns:0 frame:0
TX packets:31 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:7619 (7.4 KiB) TX bytes:7134 (6.9 KiB)
Memory:dff00000-dff1ffff
ONIE:/ # ping 192.168.0.200
PING 192.168.0.200 (192.168.0.200): 56 data bytes
64 bytes from 192.168.0.200: seq=0 ttl=128 time=9.675 ms
64 bytes from 192.168.0.200: seq=1 ttl=128 time=0.517 ms
^C
--- 192.168.0.200 ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.517/5.096/9.675 ms
3. Input "install_url [FTP account:password@location]" command and the upgrade will
start.
ONIE:/ # install_url ftp://edgecore:edgecore@192.168.0.200/AS7712-32X_FPGA_v4.updater
4. FPGA will be upgraded immediately.
- HTTP
1. Please connect to the HTTP server with Mgmt port. (e.g., AS7712-32X)
Note: Please use 1G port.
2. Set the IP address in ONIE and try to ping the HTTP server. (Server IP: 192.168.0.200)
ONIE:/ # ifconfig eth0 192.168.0.1 netmask 255.255.255.0
ONIE:/ # ifconfig
eth0 Link encap:Ethernet HWaddr CC:37:AB:C4:B1:0C
inet addr:192.168.0.1 Bcast:192.168.0.255 Mask:255.255.255.0
inet6 addr: fe80::ce37:abff:fec4:b10c/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:77 errors:0 dropped:0 overruns:0 frame:0
TX packets:31 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:7619 (7.4 KiB) TX bytes:7134 (6.9 KiB)
Memory:dff00000-dff1ffff
ONIE:/ # ping 192.168.0.200
PING 192.168.0.200 (192.168.0.200): 56 data bytes
64 bytes from 192.168.0.200: seq=0 ttl=128 time=9.675 ms
64 bytes from 192.168.0.200: seq=1 ttl=128 time=0.517 ms
^C
--- 192.168.0.200 ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.517/5.096/9.675 ms
3. Input "install_url [HTTP URL]" command and the upgrade will start.
ONIE:/ # install_url http://192.168.0.200/AS7712-32X_FPGA_v4.updater
4. FPGA will be upgraded immediately.
- SCP
1. Please connect to the OpenSSH server with Mgmt port. (e.g., AS7712-32X)
Note: Please use 1G port.
2. Set IP address in ONIE and try to ping the OpenSSH server. (Server IP: 192.168.0.100)
ONIE:/ # ifconfig eth0 192.168.0.11 netmask 255.255.255.0
ONIE:/ # ifconfig
eth0 Link encap:Ethernet HWaddr CC:37:AB:C4:B1:0C
inet addr:192.168.0.11 Bcast:192.168.0.255 Mask:255.255.255.0
inet6 addr: fe80::ce37:abff:fec4:b10c/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:77 errors:0 dropped:0 overruns:0 frame:0
TX packets:31 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:7619 (7.4 KiB) TX bytes:7134 (6.9 KiB)
Memory:dff00000-dff1ffff
ONIE:/ # ping 192.168.0.100
PING 192.168.0.100 (192.168.0.100): 56 data bytes
64 bytes from 192.168.0.100: seq=0 ttl=64 time=0.705 ms
64 bytes from 192.168.0.100: seq=1 ttl=64 time=0.433 ms
^C
--- 192.168.0.100 ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.433/0.569/0.705 ms
3. Use the "SCP" command to copy the FPGA_Updater from the SSH server.
scp [account@server ip]:[installer_file_path] [local_path]
ONIE:/ # scp jeff_cheng@192.168.0.100:/Users/jeff_cheng/Desktop/ISO/7712-32x/FPGA/AS7712-32X_FPGA_v4.updater /tmp
Host '192.168.0.100' is not in the trusted hosts file.
(ecdsa-sha2-nistp256 fingerprint md5 be:26:8f:8c:2f:26:69:f5:05:7e:30:d2
:d2:01:e0:92)
Do you want to continue connecting? (y/n) y
jeff_cheng@192.168.0.100's password:
AS7712-32X_FPGA_v4.updater 100% 636KB 635.6KB/s 00:00
4. Upgrade the FPGA by "install_url [FPGA_Updater]" command.
ONIE:/ # cd /tmp
ONIE:/tmp # ls
AS7712-32X_FPGA_v4.updater
ONIE:/tmp # install_url AS7712-32X_FPGA_v4.updater
5. FPGA will be upgraded immediately.
STEP3. After upgrade, you need power cycle the switch by manual.
STEP4. Enter the "Accton-diag" mode when the switch turns on.
STEP5. Check the FPGA version with "show_chip_ver".
root@(none):/# show_chip_ver
CPLD1 Ver (0x60).0x1 = 0a
CPLD2 Ver (0x62).0x1 = 0b
CPLD3 Ver (0x64).0x1 = 0b
CPLDFAN Ver (0x66).0x1 = 08
FPGA Ver = 0x4
STEP6. After the upgrade, please return to STEP1 and then "enable" the setting back.